Medium voltage variable frequency drive
Release time:
2022-09-07 13:47
1. Bypass function of power unit (user selectable)
When one of the cascaded power units fails, causing that power unit to stop output; resulting in the system stopping output; the bypass circuit inside the power unit is activated to bypass the output of that power unit. At the same time, the main controller inside the inverter will bypass the other two corresponding power units to ensure the three-phase voltage output of the inverter is balanced.
2. Jogging function
When the inverter receives a jogging signal, it enters the jogging working state, and the motor accelerates to the jogging frequency at a set acceleration until the jogging signal disappears.
3. Frequency skipping operation
To avoid the inverter operating at the resonance points of mechanical equipment, which could damage the motor and other devices, users can set frequency skipping to avoid certain frequency ranges.
4. Multi-segment speed operation
The inverter can operate along a set multi-segment speed curve, allowing for a maximum of 16 speed segments, with the acceleration and deceleration slopes between adjacent segments adjustable as needed.
5. Simple programmable function
The output of the inverter can change operating frequency bands based on received instructions. The acceleration and deceleration rates during frequency band switching can be set.
6. Closed-loop control function
The inverter reserves a PID controller. PID parameters can be set. The output of this PID can be used as the frequency setpoint for the inverter.
7. S-curve acceleration and deceleration
According to the needs of the production process, the acceleration and deceleration curve output by the inverter can change based on the user-defined S-curve.
8. Torque boost function
During the motor's acceleration, deceleration, and steady-state operation, this function can be set according to operational needs to boost the motor's output torque without exceeding the inverter's output current, enhancing the system's dynamic performance.
9. Parameter correction function
Designed to improve production efficiency and facilitate on-site debugging. When the inverter detects that the system input voltage, input current, system output current, and output voltage parameters do not meet specified accuracy requirements, the values detected by the testing instrument can be input through the machine's HMI interface or through backend debugging software, allowing the inverter to automatically correct the detection process to meet specification accuracy.